Fig. 4.2. Diagram of RIDZ 8x2 Switcher
With example inputs.
When the engineer hooked up the networks to the RIDZ Switcher, they also had to
connect the relay closures from the network to the 32 digital inputs for the
SMARTCASTER. KXYZ has the following closures hooked up:
SMN Magic Call Input 1
SMN Return Liner Input 2
SMN Sweep Liner Input 3
SMN Legal ID Input 4
SMN Local Break Input 5
Mutual Local Break Input 6
Mutual Legal ID Input 7
Mutual Return Liner Input 8
Rush Limbaugh Break Input 9
To map the SMARTCASTER inputs to the different networks, go to Timed Events and
press *. A list of the eight inputs for the RIDZ Switcher plus a Global Inputs selection
appears (more on Global Inputs later) and Input Diagnostics. Should the user choose the
first selection for Network #1, (SMN) they see the following: