WVRC-8 Installation and Operation Manual
INSTALLATION
Name Type Description
ST1A - 8A Connector Status opto-isolators.
When configured for DRY (factory default) this ter-
minal is ground. When configured for WET (floating),
this terminal is the anode via a 2.2K ohm current lim-
iting resistor. (BOTTOM)
ST1B - 8B Connector Status opto-isolators.
This terminal is always the cathode (BOTTOM)
K1NC - K4NC Connector Normally closed, dry relay contacts. Raise function
(TOP)
K1CM - K4CM Connector Common (wiper), dry relay contact. Raise function
(TOP)
K1NO - K4NO Connector Normally open, dry relay contact. Raise function
(TOP)
K5R - K8R Connector Normally open, dry relay contact. Raise function
(TOP)
K5R - K8R Connector Common (wiper), dry relay contact. Raise function
(TOP)
K1NC - K4NC Connector Normally closed, dry relay contact. Lower function
(BOT)
K1CM - K4CM Connector Common (wiper), dry relay contact. Lower function
(BOT)
K1NO - K4NO Connector Normally open, dry relay contact. Lower function
(BOT)
K5L - K8L Connector Normally open, dry relay contact. Lower function
(BOT)
K5L - K8L Connector Common (wiper), dry relay contact. Lower function
(BOT)
CONFIGURE Dipswitch Used to configure the unit. Refer to table of contents.
TEMP 3.5mm Jack Temperature probe input jack. T/R/S.
PF 2.1mm Jack Power Failure power jack (optically-isolated). 6 - 12
VDC,center positive.
BT-LINK Dual RJ45’s RJ45, used for future system expansion.
12VAC 2.1mm Jack System power supply input. 12 volts AC.
GND # 6 screw System ground screw. Tie to station ground system.