WVRC-8 Installation and Operation Manual
OPERATION
Dial Up Operation
When the WVRC-8 is called, it will answer on the number of rings programmed. When it answers,
enter the security code, which in this example is the default 123. The access LED will turn on
once a valid security code is entered and the “Access Accepted” Message will play. After a valid
access code is received, the addressed unit will a generate DTMF “AB” which will cause any other
units in parallel to hang up.
Raise and Lower Relays are controlled with single digits 1-8 followed by * for Lower or # for
Raise. Once a single channel number has been entered, you can enter * or # to operate the select-
ed channels raise and lower relays until a new channel number has been entered. The analog
(metering) value for the selected channel will play each time a number between 1 and 8 is entered
as long as DIP3 is off.
Example: Enter 1 – analog (metering) value 1 will play - * - The number 1 Lower relay will close
for as long as “*” is received. # - The raise relay will close for as long as “#” is received. If DIP3
is OFF, the associated relay message plus “raise” or “lower” will be played after the * or # is
released. To query the new analog (metering) value, press 1 again to repeat the value.
Audio I/O functions are controlled with the following codes, once the security code has been
entered:
01 – Local MIC Monitor ON / Feeds the local mic audio to the phone line.
02 – Local MIC Monitor OFF / Turns off feed.
03 – Telco Caller Audio Output ON / Feeds phone line (CALLER) audio to the (CLR -/+) output
terminals.
04 – Telco Caller Audio Output OFF / Turns off feed.
05 – Telco Send audio input ON / Feeds send (SND -/+) audio to the phone line.
06 – Telco Send audio input OFF / Turns off feed.
07 – SS monitor audio to telco ON / Feeds Silence Sensor source audio (SS-LT/SS-RT) to the
phone line.
08 – SS monitor audio to telco OFF / Turns off feed.
The status inputs, analog (metering) inputs, silence sensor, temperature and
power fail inputs can be polled by entering the following codes.
Polling Silence Sensor Alarm: 910
Polling Status inputs: 911 - polls input 1, 912 - polls input 2 …. 918 polls input 8.
Polling Power Failure: 919
Manual Hang-up: 920 will cause the WVRC-8 to hang up.
Polling Analog (metering) inputs: 921 - polls analog (metering) input 1, 922 - polls analog
(metering) input 2 ….. 928 polls analog (metering) input 8
Polling temperature: 929
DTMF Control of Alarm Enable Registers 97, 98 & 99)
All of the alarm call-outs can be enabled, disabled or polled remotely using DTMF control. First
enter the access code.