ProMix 12 Installation and Operation Manual
INSTALLATION
2.2 CONTROL INTERFACE
2.2.1 MICROPHONE 2 & 3 REMOTE CONTROL
The console provides for remote control of Microphone 2 and Microphone 3 via the
Microphone 2 & 3 Remote Control connector (9). This 15-pin D connector should
be wired according to Figure 2.
Note that “cough switches” for microphones 2 & 3 can be installed for use by the
console operator if these microphones will be used in the studio. If these cough
switches are not used, jumpers (see note below) must be installed as shown between
pins 9 & 10 and between pins 13 & 15. Mics 2 & 3 will not operate if these jumpers
are missing.
Cough switches can also be installed for remote use, as shown connected to the
remote ON switches. If the “cough switches” are not used, jumper wires must be
installed in their place (See note below).
NOTE: On version A & B, jumpers JP1 (Mic-1) and JP4 (Mic-2) may be
installed on the main circuit assembly (the bottom cover must be removed to
access these jumpers), eliminating the need to solder jumpers on the connector.
LEDs can be used to show “Microphone ON”; be sure to include the 1K resistors as
shown. (This value can be changed to set LED brightness.)
The Talkback function allows the booth announcer to talk directly to the console
operator (off-air) via the Talkback system.
The MUTE TALLY relay on pin 4 (ground is pins 1 & 5) provides a means of
switching external equipment when the monitor mutes. The relay contact goes to
ground when the monitor is muted. It can be used to operate “ON AIR” warning
light controllers, etc. Contact rateing are 30vdc @ 1amp or less. DO NOT
EXCEED THIS RATING. NEVER CONNECT THESE CIRCUITS TO A 110
VOLT AC LINE!
2.2.2 LINE CHANNEL REMOTE CONTROL
The console provides 9 momentary SPST switches than can used for “remote start”
of line channel source equipment, e.g, CD players, tape decks, etc. Interface to these
switches is via Line Channel Remote Starts connector (10), a 25-pin D connector.
WARNING: The maximum voltage that can be applied to Remote Start switches is
24vdc @ 100ma or less. DO NOT EXCEED THIS RATING. NEVER CONNECT
THESE CIRCUITS TO A 110 VOLT AC LINE! Connect the mating 25-pin D con-