5-24 Section 5: Module Configuration
Moseley SL9003Q 602-12016 Revision G
5.9.3.2. Mapping Set 2 and “Map Faults-Relays” Set ON
Relays remain the same as for Mapping 1 but analog output is manually selected by
performing the following steps:
On the SL9003Q Tx Main Menu
Use Up or Down arrow to select System
<Enter>
Scroll down to External I/O
<Enter>
Scroll down four times
Use left or right arrow to set analog output (see table in Mapping 1)
<Enter>
<Escape>
<Escape>
Use left or right arrow to select Yes to save settings
<Enter>
5.9.3.3. Mapping Set 0 and “Map Faults-Relays” Set ON
Analog output is manually selected. The relays are set as follows (refer to section 4.4.10
for corresponding menu screens):
Relay 1 pins 7 (-) and 8 (+)
Receiver Synth UNLock Status Exist or Equipment Power Off
Relay 1 = Off (Set Open)
Receiver Synth Lock Status Exist and Equipment Power On
Relay 1 = On (Set Closed)
Relay 2 pins 5 (-) and 6 (+)
One or more Transmitter Alarm Status Exist or Equipment Power Off
Relay 2 = Off (Set Open)
No Transmitter Alarm Status Exist and Equipment Power On
Relay 2 = On (Set Closed)
Relay 3 pins 3 (-) and 4 (+)
QAM Mod UNLock Alarm Status Exist or Equipment Power Off
Relay 3 = Off (Set Open)
QAM Mod Lock Alarm Status Exist and Equipment Power On
Relay 3 = On (Set Closed)
Relay 4 pins 1 (-) and 2 (+)
Demod UNLock or Equipment Power Off
Relay 4 = Off (Set Open)
Demod Lock and Equipment Power On
Relay 4 = On (Set Closed)