5 - 9
Decode Section
The Decode section specifies decoder settings when using the decoder with ScanWedge.
ScanWedge Entry Description Default
Value
Available Values
Enable Enables and disables the decoder for
ScanWedge.
1
0=Disabled; decoder is not used.
1=Enabled; decoder sends bar
code data as keystrokes to the
active window.
Trigger Sets the key used by ScanWedge to
initiate a scan/decode. The key is
registered as a system hotkey and
cannot be registered as a hot key by
any other applications.
42
42=OnScan or Scan key
ContScan Enables and disables continuous
scan.
0
0=Disabled; trigger key must be
released between scans.
1=Enabled; data is continuously
decoded and sent to the
application while the trigger key
is depressed.
PowerSave Enables and disables power saving
mode.
Note: This key does not appear in the
ScanWedge.exm file for the
Dolphin 6100/6500/7600.
1
1=Enabled; the decoder
automatically initializes and un-
initializes as needed. A slight
delay occurs when the trigger is
activated.
0=Disabled; the decoder initializes
when the utility starts and un-
initializes when the utility
terminates.
ScanTimeout Specifies the decode time out in 1/
1000th seconds. If a barcode is not
decoded within the specified timeout
an audio and visual notification
indicates that an error occurred.
5000
X=Time in 1/1000th of a second.
ScanMode Specifies the decode mode. 1
1=Full Omni/Normal
2=ALD (Aggressive Linear
Decode) mode
4=Quick Omni
LinearRange Specifies the linear search range to
be used while in ALD mode.
3
X=Range from 1 to 6.
1 indicates a tight vertical range
near the aimer.
6 indicates a vertical range of
the entire height of the imager.
Vista de pagina 84