Broadcast Tools SS 2.1/Terminal III Especificaciones Pagina 40

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 42
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 39
40
APPENDIX
Functional Diagram
SITE
Sentinel
®
16
Sixteen Channel Web Enabled Site Remote Control System
+5.0VDC
+12VDC
Raise
Relay Status
10/100 baseT NET/RJ-45
Reset
Defaults
Universal regulated 12VDC
External Power Supply (Supplied)
PS
1-16 Metering Inputs. Each output
accepts up to 10vdc.
Plug in euroblock connectors
VCC
Temp Probes
4 probes max
2.2k
Monitor/
Control
CPU
JP
Left
Power Failure Input Opto-Isolated
2.1mm Coax Connector
+3.3VDC
–12VDC
Web
Server
Link
Activity
RFI Filter
16 Input
12 Bit A/D
Raise Relays 1-16 SPDT DRY
30vdc @ 1 Amp contacts.
Lower Relays 1-16 SPDT DRY
30vdc @ 1 Amp contacts.
Plug in Euroblock Connectors
Opto-isolated Wet or Dry Status Inputs 1-16
Plug in Euroblock Connectors
Power Controller – Plug in Euroblock
Gnd
Right
Silense Sensor Input
Plug in Euroblock Connectors
Lower
Relay Status
Status
Power
Heartbeat
Power
Controller Status
Power
Failure Status
Silense
Sensor Status
1-16
1-16
Local Control
A
B
Vista de pagina 39
1 2 ... 35 36 37 38 39 40 41 42

Comentarios a estos manuales